|
PACKAGE SPECS
AT-A-GLANCE |
||||
| CABINETS AND HARDWARE: |
Merillat – Sundale - Maple Front frame 3/4" solid hardwood. Doors – standard overlay; mortise and tendon frame with raised panels Concealed self-closing hinges Tops and bottoms are 1/2” engineered wood. Drawer bodies are lap jointed and bonded with adhesive and stapled. Shelves are 5/8” engineered wood with melamine edge banding laminated on front edge. Drawer guides are exclusive extra quiet whisper glide with nylon rollers. Base cabinets utilize half depth shelves except sink bases. |
|||
| COUNTERTOPS: |
Formica brand self-edged 1 1/2" x 25" with 4" backsplash. Choice of colors. (with the exception of the “Premium Plus” models, which are not included in the package and are to be provided by the Builder) (FORMICA LAMINATE REFERENCE CHART) |
|||
| VANITY TOP: |
Cultured (synthetic) marble top-color white on white standard Oval shaped bowl – as per print 4" backsplash 20” x 18” Pedestal sink per individual plan where shown. |
|||
| MEDICINE CABINET: | MIRROR DOOR - OAK - SURFACE MOUNT - LIGHT BAR | |||
| TUBS/SHOWERS: | TUB/ SHOWER | SHOWER | SOAKING TUB | OPTIONAL WHIRLPOOL |
|
Lasco or equal - one piece unit - white Tub shower - multi level Shelves - recess soap dishGrab bar Right or left drain 60" x 32" x 72 Meet or exceeds requirements: all tubs, HUD/FHA;ANSI;listed with IAPMO/SBCCI
|
||||
| WATER CLOSETS: |
White Mansfield China (or equal) 12" rough-in 86 lb. Water surface 8x9” 1.6 qpg – 60 Lpf, ULF Gravity-Fed flushing 5-yr. Warrant Meets/exceeds requirements: Fed specs WW P541 F GEN: 1980 WWP541/4B: 1980 |
|||
| KITCHEN SINK: |
Nickel Bearing stainless steel satin tone finish 8" deep (2) 14" x 14" bowls Undercoating treatment for bowl to deaden sound and inhibit condensation 18.8 type 301 AH-40 3 1/2" drop in basket strainer with brass locknut |
|||
| FAUCETS: |
Delta – single lever/ knob Delta – Model 522TP w/pop-up Delta – Model 400TP w/spray Delta – Model 13422 monitor (Tub) Delta – Model 13222 monitor (Shower) All faucets are chrome All faucets meet or exceed requirements CSA certified B-125 ANSI A 112.18.1M IRC 2006 NSPC SBC UPC Led spec: WWP-541/4B; WWP-541/7C; WWS-1913A |
|||
| WATER HEATER: |
ProLine or equivalent residential - 50 gallon capacity electric
Anode Rod to maximize tank life Screw-in heat elements Fused ceramic shield 240 volt, 4,500 watt elements Meets or exceeds requirements U.L. listed 3/4";NPT 3/4" electric conv; certified; 150 PSI working; 300 PSI test Electric M-I 50 S5DS 20" diameter 58 1/2” high 20.7 GPH recovery 80 degree Fahrenheit rise 115 lb. U.L. approved |
|||
| HANDRAIL: |
Main stairs- Pine handrail Open spindle side stairwells, and balconies (per plan) Pine stair rail system Basement stairs- WM - 1203 pine handrail Saf-stair rail system included for all basement stairs |
|||
| RAIL SYSTEM: |
OPEN SPINDLE SIDE STAIRWELLS, AND BALCONIES (PER PLAN)
SAF-STAIR RAIL SYSTEM INCLUDED FOR ALL BASEMENT STAIRS |
|||
| DOOR KNOBS: | SCHLAGE - BRIGHT BRASS LOCKSETS | |||
| INTERIOR DOORS: |
Pre-hung/Split jamb - Colonist or equal 6 panel hollow core “Colonial" design hinged include cased openings and bifold doors (flat back) Location per prints - with wood split jambs (paint grade) Hinged doors are pre-hung with 3-hinge assembly to minimize warpage 1 3/8" standard thickness and dimension on prints All doors are primed for painting |
|||
| INTERIOR TRIM: | 3" COLONIAL-STYLE BASEBOARD | |||
|
CLOSET SHELVES: Pic#1 Pic#2 |
CLOSET MAID VINYL CLAD VENTILATED SHELVING | |||
| HARDWOOD FLOOR: | 3/4” SOLID OR 3/8” MANUFACTURED – Optional upgrade | |||
| CARPET: |
Beaulieu Promo 836 Carpet 100% polyester pile, 29 oz. Approved carpet stain protector Choice of color 3/8" bonded pad included 6lb density or equal |
|||
| VINYL: |
FHA (ETL #) 21269 DOMCO – “CustomFlor” sheet vinyl flooring with 5-year limited warranty "No-wax" finish Meets HUD and FHA minimum wear layer thickness requirements CSA 126.3 Grade 3 Type 1 CCMC 09551 FHA LF 001641 Amend 1, Type III, Class 3 Choice of patterns and colors |
|||
| APPLIANCES: |
Whirlpool Range - 30” 4.8 cu. Ft. 4 burner, self cleaning Electric Whirlpool Range Hood – 30”, non-vented ductless Whirlpool Dishwasher- 5 level, Energy Star, White or Black | |||
| LIGHT FIXTURES: | SL 8763-1 KITCHEN M 2205-1 DINING ROOM SL 8260-1 NOOK, ETC | |||
| ELECTRICAL MATERIALS: |
40 opening - 40 circuit capacity Square/D Homeline or equal 200 amp service panel with breakers Duplex outlets and wall switches per prints Ground Fault Interrupter outlets in kitchens and baths Front and rear elevation ground fault interrupter exterior circuit All copper electrical wire for outlets, switches, fixtures and appliances (sized per prints) Ivory color is standard light fixtures provided per prints - see literature for fixture specifications AC/DC smoke detectors (can be wired in series) Meter base (Met-Ed & PP&L approved) |
|||
| MISCELLANEOUS: |
All necessary caulking provided for siding and accessories Shim shingles, nailers, 2x4 temporary bracing included |
|||
|
PRODUCTS AND
MANUFACTURERS ARE SUBJECT TO CHANGE WITHOUT NOTICE. |
||||
|
Lancaster Redevelopment Corporation provides further information via its product manual. All Builders must familiarize themselves with standard and optional specifications, as well as exclusions from Lancaster Redevelopment Corporation material packages. Builder must provide foundation, all other masonry materials, 1st floor sub-floor deck system, insulation, drywall, paint, mirrors above vanities and pedestal sinks, heating system, rough plumbing, garage doors, framing nails, roofing nails, siding nails and certain other items. These materials supplied by Builder to complete construction may be depicted in Lancaster Redevelopment Corporation drawings to facilitate construction permits, subcontractor relations, etc., but such depiction does not constitute a representation that Lancaster Redevelopment Corporation is providing them; only that they are necessary to complete construction. Please consult an Authorized Representative and Purchase Agreement for further details.
|
||||