PACKAGE SPECS
AT-A-GLANCE |
|
| PLEASE NOTE THAT THE SPECS HAVE CHANGED 10/24/2008 | |
| INT. / EXT. WALLS: |
LANCASTER REDEVELOPMENT
CORPORATION FACTORY ASSEMBELED PANELS: 2"x4" studs 16" o.c. SPF grade Plates and headers #2 SPF 19% maximum moisture content Meets or exceeds NLGA rules; ALS approved Garage walls and slab foundations only-bottom plates pressure treated 2" x 6" studs 16" O.C. for interior HVAC walls - per individual models when applicable |
| WALL SHEATHING: |
House and Garage 7/16” OSB screen back Meets or exceeds requirements of IRC 2006 ICBO FHA/HUD |
| 2ND FLOOR FRAMING: |
NOTE:
First floor system by Builder per plans |
| 2ND SHEATHING: |
3/4" x 4’ x 8’ tongue & groove OSB with construction adhesive (shipped loose) Meets or exceeds requirements of NER 108 HUD/FHA TECO |
| ROOF FRAMING: |
Lancaster Redevelopment Corporation pre-assembled trusses - 6/12 pitch typical or per individual plan Trusses typically 24" o.c. per design drawings (16" overhang at eaves) 30 PSF live load Alpine truss plates Truss plates - 20 ga. Meets or exceeds requirements of FHA and IRC 2006 codes Note: All Cape Cod styles are a pre-cut rafter system 2 x 6 SPF #2 fascia board |
| ROOF SHEATHING: |
7/16" OSB 4x8 NER-108 rating Aluminum H-clips provided for use between centers Meets or exceeds requirements of HUD/FHA TECO |
| ROOFING: |
Shingles-Tamko Heritage architectural – 30-year warranty Tamco hip and ridge supplied for shingle cap Shingles Class “A" type 1 12" x 37" with 5" exposure Meets or exceeds requirements of ASTM - D 3462-83 and D-3018-82 U.L. approved Fed. spec SS-S-001534 Underlay-Felt shingle underlayment #15 Grade 36"x 144' roll (covers 432 sq. ft.) Meets or exceeds requirements of U.L. approval - prepared roofing necessary Air vent - rolled shingle over Drip edge - all sides |
| MAIN STAIRS: |
TREADS - 5/4" OAK - BULL NOSE ONE SIDE RISERS - 1" X 8" OAK STRINGERS - 5/4" X 10" OAK STAIN GRADE |
| BASEMENT STAIRS: |
TREADS - 5/4" X SYP - BULL NOSE ONE SIDE RISERS - 1" X 8" PONDEROSA PINE #2/BTR STRINGERS - 2" X 10" SPF OR SYP # 1 OR BTR CARPET GRADE |
| WINDOWS: |
Single-hung tilt vinyl windows or vinyl casements per plan Meets or exceeds requirements of ASHRAE codes Bottom sashes are operable Half Screen’s included throughout Casement (on certain models per plan) Fixed glass panel (on certain models) trapezoidal or transom Integral J channel where applicable Factory assembled “Quick-Trim” (2 ¼ “ casing, apron, jamb & sill in a single assembly) Factory applied Vycor Plus self-adhered flashing to header’s, sill’s and jamb’s Grilles are available as an option One designated window per plan will be factory installed with screws to allow for drywall stocking. |
| WINDOWS TRIM: | FACTORY ASSEMBLED “QUICK-TRIM” MOLDING |
| ENTRY DOORS: |
Therma-Tru or Benchmark polystyrene core-insulated steel clad six panel entry door or per plan (location per prints Therma-Tru or Benchmark polystyrene core-insulated steel clad #263 sidelights (main entry door only, per prints) Thermal break construction Thermal break aluminum threshold Compression weather-stripping Composite sill Prime painted Solid lock block 25 ga. steel Thermal transmission R Value 7.22 Vycor Plus self-adhered flashing for head’s, jamb’s and threshold’s (shipped loose) |
| SIDELIGHTS: | THERMA-TRU OR BENCHMARK POLYSTYRENE STEEL CLAD #263 |
| PATIO DOOR: |
Therma-Tru Single Active Steel Swing Patio Door or Capital Vinyl Sliding Glass Door as per individual plan. |
| SIDING: | Norandex Summit Manor Series - Double 4 ½” or Dutchlap 4 ½” design solid vinyl |
| STONE SIDING: |
2 1/2" surface applied stone (per individual model) Galvanized wire lath shipped loose Corner stones, electrical box stones, windowsill stones, shutter block stones, soldier stones, and (as required per individual model) Type S mortar for skim coat, and grout must be BUILDER SUPPLIED at time of application |
|
EXTERIOR
ACCESSORIES: Pic#1 Pic#2 |
Norandex or equivalent vinyl soffit-fully vented except cantilever overhangs, gable overhangs, porch ceilings ¼ vented, ¾ solid Aluminum fascia Vinyl F channel & J channel accessories Mid-America light fixture blocks - match siding, color Meets or exceeds HUD minimum requirements and AAMA standards Starter strips & undersill trim Choice of colors Exposed rafter tail assembly where shown on “Low Country” models |
| SHUTTERS: |
15" wide 1 1/8" thick One piece construction wood grain texture Open louver - raised panel shutters available as option Front elevation only (per individual plan) |
| ELECTRICAL: |
40 OPENING - 40 CIRCUIT CAPACITY - 200 AMP SERVICE PANEL ALL COPPER ELECTRICAL WIRE DUPLEX OUTLETS AND TOGGLE SWITCHES – IVORY STANDARD LIGHT FIXTURES PROVIDED PER PRINTS AC/DC SMOKE DETECTORS |
| INSULATION: | FIBERGLASS KRAFT FACED |
| MISCELLANEOUS: | ALL NECESSARY NAILS ARE INCLUDED WITH HOUSE SCREWS AND CAULKING PROVIDED FOR SIDING AND ACCESSORIES SHIM SHINGLES, NAILERS, 2X4 TEMPORARY BRACING INCLUDED |
|
PRODUCTS AND